Transformer Core Grounding Current Monitor | Oman 2026
video
Transformer Core Grounding Current Monitor | Oman 2026

Transformer Core Grounding Current Monitor | Oman 2026

Country: Oman 2026
Quantity: 2
Material of hose: 316 stainless steel metal
Model: ALS50A-0.5 (10)A/3.53V
Power supply voltage: ±12V
Frequency range: 50Hz (400Hz)

Description

 

Oman Ibri Standalone BESS Plant Project-219
Oman Ibri Standalone BESS Plant Project-220
Oman Ibri Standalone BESS Plant Project-221
Oman Ibri Standalone BESS Plant Project-223
Oman Ibri Standalone BESS Plant Project-224

 

Grounding insight, guarding the iron core - integrated protection within your monitor.

General

 

Project Description

The Duqm 500MW/2000MWh Battery Energy Storage System (BESS) project in Oman is a grid side energy storage project led by the Oman State Grid Corporation (OETC), located in the Duqm Special Economic Zone. This project is positioned as the "core stabilizer" of the North South Interconnection Channel in Oman, providing power security for local industrial areas and achieving cross regional peak valley regulation. Energy storage power stations involve multiple step-up transformers, and their safe operation is crucial for the reliability of the entire energy storage system.

To ensure the safe operation of the transformer equipment in the project, an ALS50A-0.5 (10) A/3.53V transformer core grounding current online monitoring device is installed. As an independent intelligent monitoring unit, this device monitors the grounding current of the transformer core and clamps in real time, used for early detection of multi-point grounding faults caused by insulation degradation.

The monitoring module of this project adopts a design concept similar to that of the Kazakhstan project - real-time acquisition of current signals on the grounding leads of the iron core and clamps through high-precision sensors. Unlike the Kazakhstan project, which integrates modules into oil chromatography analyzers, the Oman project uses independent monitoring modules for flexible deployment and maintenance.

 

Oman Ibri Standalone BESS Plant Project-229

 

 

Technical Specification

Delivered to

Oman

Year

2026

Standard

GB11022,DL/T 596-1996,DL/T 572-95,QBO11-RX2009

Model

ALS50A-0.5 (10)A/3.53V

Measurement current range

0-50OmA AC/0-3.53V AC

Measurement current range

0-10A AC/0-3.53V AC

Power supply voltage

±12V

Frequency range

50Hz (400Hz)

Operating temperature

-40°C to +85°C

 

Drawings

 

product-1490-1054

 

Manufacturing

 

Current sensor

product-447-637

In the online monitoring device for transformer cores, the ALS50A-0.5(10)A/3.53V sensor serves as the front-end sensing core component, specifically designed for real-time detection of leakage currents in the grounding leads of transformer cores and clamping pieces.

The sensor boasts exceptional sensitivity, capable of precisely measuring minute current variations at the microampere (μA) level, effectively capturing early-stage characteristic quantities such as initial insulation moisture ingress and core multi-point grounding faults.

 

Testing

 

No.

Inspecting item

Standard requirements

1

Appearance inspection

Surface clean, scratch-free, with correct labeling and accessory packaging

2

Basic error measurement

Test specification ( mA)

Output 1 (V)

Output 2

(V)

Test specification

(A)

Output 1 (V)

Output 2

(V)

Bear fruit

0

0.00023

0.00020

0

0.00013

0.00012

Qualified

25

0.172

0.172

0.5

0.174

0.173

100

0.704

0.704

2

0.705

0.706

250

1.765

1.765

5

1.761

1.765

400

2.825

2.824

8

2.823

2.825

500

3.532

3.533

10

3.533

3.535

600

4.239

4.240

12

4.242

4.243

3

Insulation resistance

The input voltage to the chassis must be≥20MΩ

Qualified

4

Insulation strength

Power input terminal to the housing, industrial frequency, 15oov,1 minute

 

Oman Ibri Standalone BESS Plant Project-3409
Oman Ibri Standalone BESS Plant Project-3412

 

Packing and Shipping

 

Packing

 

Oman Ibri Standalone BESS Plant Project-3439
Oman Ibri Standalone BESS Plant Project-3441

 

Shipping

 

Oman Ibri Standalone BESS Plant Project-3468
Oman Ibri Standalone BESS Plant Project-3470

 

Site and Summary

 

The Core Grounding Online Monitoring Module represents a vital complement to transformer diagnostic technology, offering enhanced detection of multi-point grounding faults and improved operational safety. Integrated as an IED backend module within the Transformer Dissolved Gas Analyzer, the system features a high-precision current sensor (ALT50A7-10A/A1) installed on the core and clamp grounding down conductors. It continuously monitors grounding currents from 0 to 10A AC with 4-20mA DC output, enabling early warning of insulation deterioration before faults escalate. With seamless IEC 61850 integration, robust terminal connections (SAKEW35, SAKDU 2.5N), and compliance with GB/T 11022, DL/T 596-1996, DL/T 572-95, and QBO11-RX2009, this module delivers reliable performance under harsh environmental conditions. As utility operators and industrial clients prioritize predictive maintenance and asset protection, the Core Grounding Online Monitoring Module will play an essential role in safeguarding transformer iron cores, complementing dissolved gas analysis for a complete, intelligent, and resilient power infrastructure for Kazakhstan and beyond.

 

Oman Ibri Standalone BESS Plant Project-4655

 

Hot Tags: transformer core grounding current monitor | oman 2026, China transformer core grounding current monitor | oman 2026 manufacturers, suppliers, factory, dga analysis for transformer condition monitoring, winding hot spot temperature monitoring, Transformer Core Grounding Current Monitor, Online Partial Discharge Monitoring System for Transformer, dissolved gas analyzer for transformer oil, Transformer Dissolved Gas Analyzer

You Might Also Like

Shopping Bags