Blog
-
18
Jul-2026
Power System Neutral Grounding Methods: A Complete Guide for Electrical EngineerIntroduction In electrical power systems, the way the neutral point of a transformer or generator is grounded plays a critical role in determining the system's safety, reliability, and insulation
-
16
Jul-2026
Classification, Mechanism and Comparative Analysis of Power System Overvoltages📋 Table of Contents External Overvoltages: Lightning-Induced Surges Internal Overvoltages: System-Generated Transients Temporary Overvoltages Switching Overvoltages Resonant Overvoltages Summary Comp
-
15
Jul-2026
Power System Overvoltage Types: Causes, Effects, and Protection Strategies fo...Power System Overvoltage Types: Causes, Effects, and Protection Strategies for Medium-Voltage Equipment Understanding overvoltage is essential for protecting transformers, switchgear, and cable system
-
27
Jun-2026
Epoxy Resin Dry Type TransformerEpoxy Resin Dry Type Transformer Everything you need to know about cast resin dry type transformers - from core technology and safety features to installation best practices and application scenarios.
-
13
Jun-2026
Surge Arrester Monitoring Guide: Normal Operating Parameters, Leakage Current...A reliable Surge Arrester Monitoring system is essential for protecting high-voltage electrical equipment from overvoltage damage. By continuously tracking leakage current and cumulative action counts
-
13
Jun-2026
SF6 Gas Monitoring System Installation Guide: Best Practices for Detector Pla...In high-voltage switchgear rooms, GIS rooms, and other power facilities, an SF6 gas monitoring system is a critical technology for ensuring equipment safety and personnel health. Proper installation n
-
16
May-2026
Transformer Winding Hot Spot Monitoring - Fiber Optic Installation and Mainte...Fiber Optic Installation and Maintenance Operating Procedures I. Personnel Qualifications and Basic Fiber Optic Operation Procedures 1. Fiber optic installation and maintenance must be performed by ri
-
16
May-2026
Online partial discharge monitoring system for transformer - Guidelines for U...Guidelines for Use and Maintenance 1. Introduction to System Composition This system mainly consists of three parts: Perception unit: including ultra-high frequency, high-frequency current, and ultras
-
16
May-2026
Precautions for Operation and Maintenance Personnel of transformer dissolved ...Precautions for Operation and Maintenance Personnel 1. Routine Inspection Regularly inspect to verify data normality. Check system status after any power switching. Monitor carrier gas pressure gauge
-
08
Apr-2026
Pre-Operational Inspection Summary Fot Station Service Transformer1. Basic Condition Check Verify equipment integrity through visual examination. Confirm porcelain bushings are clean and undamaged; check for oil leaks on tanks and radiators; ensure nameplates and ma
-
06
Apr-2026
Oil-Immersed Transformer: Pre-Operation ChecklistI. Visual & Sealing Inspection Verify structural integrity and sealing: Check bushings, tank, radiators, and conservator for damage, leaks, or corrosion. Ensure nameplate/phase markings are legibl
-
27
Mar-2026
Product Installation of Dry-type Transformers1. Foundation Condition Inspection Confirm that the winding surface is clean and undamaged, and the insulation is normal; the grounding bolts of the core, clamps, and casing are securely tightened. Ch