Oil Immersed Distribution Transformer
11kV/0.4kV 2000kVA Dyn11 Copper Winding ONAN Oil-Immersed Distribution Transformer
Description
1. Product Overview
The Oil-Immersed Distribution Transformer is designed to step down medium-voltage electricity to a low-voltage supply for industrial, commercial, and utility power distribution systems. With a rated capacity of 2000kVA, this three-phase transformer features copper windings, a Dyn11 vector group, and ONAN (Oil Natural Air Natural) cooling.
Its oil-immersed insulation system provides electrical insulation and heat dissipation for the core and windings, while the ONAN cooling arrangement supports continuous operation without requiring forced-cooling fans or oil pumps in the standard configuration. The Dyn11 connection provides a star-connected low-voltage winding with an accessible neutral terminal, making the transformer suitable for three-phase four-wire distribution networks.
Equipped with an off-circuit tap changer, the transformer allows the voltage ratio to be adjusted to accommodate different network operating requirements. It is suitable for distribution substations, industrial facilities, commercial buildings, and infrastructure projects requiring a stable 400V low-voltage power supply.
2. Key Features and Advantages
- 2000kVA Rated Capacity: Designed for medium-sized and large power distribution applications, providing an 11kV primary voltage and 0.4kV secondary voltage for downstream electrical loads.
- Copper Winding Construction: Uses copper conductors for the high-voltage and low-voltage windings, offering good electrical conductivity, mechanical strength, and thermal performance under normal operating conditions.
- ONAN Cooling System: Uses natural oil circulation inside the transformer and natural air circulation outside the tank to dissipate heat, simplifying the cooling structure and reducing dependence on auxiliary cooling equipment.
- Dyn11 Vector Group: Features a delta-connected high-voltage winding and a star-connected low-voltage winding with a neutral terminal. The connection provides a 30° phase displacement between the high-voltage and low-voltage winding phasors.
- Off-Circuit Voltage Regulation: Allows adjustment of the transformation ratio through selectable tap positions to accommodate variations in supply voltage. Tap changes must only be performed when the transformer is completely de-energized and isolated.
3. Technical Specifications
|
Parameter |
Specification |
|
Product Name |
Oil-Immersed Distribution Transformer |
|
Rated Capacity |
2000kVA |
|
Primary Rated Voltage |
11kV |
|
Secondary Rated Voltage |
0.4kV |
|
Number of Phases |
Three Phase |
|
Winding Material |
Copper |
|
Vector Group |
Dyn11 |
|
Cooling Method |
ONAN |
|
Voltage Regulation |
Off-Circuit Tap Changer |
|
Rated Frequency |
To Be Confirmed |
|
Tap Range |
Project-Specific |
|
Short-Circuit Impedance |
Project-Specific |
|
No-Load Loss |
According to Approved Design |
|
Load Loss |
According to Approved Design |
|
Applicable Standard |
IEC 60076 series, subject to project requirements |
Note: Final technical parameters shall be confirmed in the approved technical datasheet and manufacturing specifications. Frequency, tap range, impedance, and guaranteed loss values can be configured according to project requirements.
4. Structural Design and Main Components
-
Magnetic Core
- The magnetic core provides the main magnetic path for energy transfer between the high-voltage and low-voltage windings. Its material and laminated construction are selected to meet the required electrical performance and core loss specifications.
-
Copper Windings
- The high-voltage and low-voltage windings are manufactured using copper conductors. The winding arrangement and insulation structure are designed to withstand operating voltage, thermal stress, and electrodynamic forces during short-circuit events.
-
Oil-Immersed Insulation System
- Transformer oil serves as both an insulating and cooling medium. It provides dielectric insulation between energized components and transfers heat generated by the core and windings to the cooling surfaces of the transformer.
-
Transformer Tank and Cooling Structure
- The transformer tank houses the active part and insulating oil. Heat is transferred from the internal oil to the surrounding air through the tank and its cooling structure, following the ONAN cooling principle.
-
Off-Circuit Tap Changer
- The off-circuit tap changer provides selectable winding connections for adjusting the voltage transformation ratio. It must be operated only after the transformer has been disconnected from the power supply and confirmed de-energized.
5. Typical Applications

- Industrial Power Distribution
- Used in manufacturing plants, processing facilities, mining operations, and industrial production lines to step down 11kV power for low-voltage equipment and distribution systems.
- Commercial Buildings
- Suitable for shopping centers, office buildings, hotels, and large commercial facilities requiring a reliable low-voltage electricity supply.
- Distribution Substations
- Installed in utility and private distribution substations to convert medium-voltage electricity into 400V low-voltage power for downstream consumers.
- Infrastructure Projects
- Applied in transportation facilities, water treatment plants, public utilities, and other infrastructure developments requiring medium-voltage power distribution.
- Renewable Energy Projects
- Can be used for auxiliary power distribution in solar and wind energy facilities when the transformer voltage, capacity, and electrical configuration match the project requirements.
6. Manufacturing and Quality Control
Reliable transformer performance depends on material selection, winding workmanship, core assembly, insulation treatment, and factory inspection. Each manufacturing stage is controlled to ensure that the finished transformer meets the approved technical specifications.
Typical inspection and testing procedures include:
- Visual and Dimensional Inspection: Checks the overall appearance, component installation, dimensions, and assembly quality.
- Winding Resistance Measurement: Verifies the electrical resistance of the high-voltage and low-voltage windings.
- Voltage Ratio and Vector Group Test: Checks the transformation ratio and confirms the specified Dyn11 connection.
- Insulation Resistance Measurement: Evaluates the insulation condition between windings and between windings and earth.
- Dielectric Tests: Includes the applicable applied voltage and induced voltage withstand tests.
- No-Load Loss and Current Measurement: Evaluates the transformer's excitation performance under no-load conditions.
- Load Loss and Impedance Measurement: Checks load-related losses and short-circuit impedance against the approved design values.
- Tank Sealing and Leakage Inspection: Checks the tank and sealing arrangements to help prevent transformer oil leakage.
Routine tests are conducted in accordance with the applicable IEC 60076 requirements and the approved technical agreement. Additional type tests or special tests can be arranged when specified by the project.
7. FAQS
Q: What does 11kV/0.4kV mean in a distribution transformer?
A: It indicates the rated voltage levels of the primary and secondary windings. The transformer steps down the incoming 11kV medium voltage to a nominal 0.4kV low-voltage supply for distribution applications.
Q: What does Dyn11 mean in a transformer?
A: Dyn11 represents the transformer winding connection and vector group. The high-voltage winding is delta-connected (D), while the low-voltage winding is star-connected with a neutral terminal (yn). The clock notation 11 indicates a 30° phase displacement, with the low-voltage phasor leading the corresponding high-voltage phasor by 30° under the standard clock convention.
Q: What are the benefits of ONAN cooling?
A: ONAN cooling uses natural oil circulation and natural air circulation to remove heat generated inside the transformer. It does not require forced-cooling fans or oil pumps in the standard ONAN configuration, helping simplify the cooling arrangement and routine maintenance.
Hot Tags: oil immersed distribution transformer, China oil immersed distribution transformer manufacturers, suppliers, factory, immersed transformer, oil filled distribution transformers, oil filled transformer sizes, oil immersed self cooled transformer, Station Service Transformer, three phase oil immersed transformer