Epoxy Resin Dry Type Transformer
Epoxy resin dry type transformer is a high safety power equipment that uses epoxy resin as the insulation medium and vacuum casting technology to encapsulate the coil as a whole. Epoxy resin is flame-retardant and does not produce toxic gases even when burned. Additionally, it has strong environmental adaptability and can operate stably in a 100% humidity environment. It is designed for high-rise buildings, data centers, hospitals, subways, airports, commercial centers, chemical plants and other places with high fire safety requirements and limited installation space, meeting the high reliability power supply needs in complex environments.
Description
Details page content
I. A brief product introduction
This product uses high-quality epoxy resin and glass fiber as its core materials, possessing excellent insulation performance and high-temperature resistance. Utilizing a vacuum casting process, it ensures dense, bubble-free coil molding, resulting in high overall structural mechanical strength, excellent impact and vibration resistance, and effectively extending product lifespan.
Regarding service and compatibility, this product has experience supplying projects to the State Grid and Southern Power Grid, and supports customized solutions based on customer needs. We provide full lifecycle technical support and maintenance services, and free handling of quality defects during the warranty period, ensuring long-term stable operation of the equipment and comprehensively guaranteeing the reliability and security of the user's power system.
II. Model Explanation

III. Product Details/Advantages

Safety & Environmental Protection:
Oil-free design eliminates fire hazards, and the epoxy resin emits no toxic gases when burned, meeting environmental standards.
Easy Maintenance:
Compact, highly integrated structure requires no regular oil checks-only surface dust cleaning-reducing maintenance effort and costs.
Adaptability to Complex Environments:
Excellent resistance to moisture, condensation, and pollution ensures reliable operation in harsh conditions like high humidity and dust, eliminating the need for a dedicated equipment room.
Energy Efficiency:
Utilizes low-loss silicon steel sheets and optimized coil design, achieving no-load and load losses far below national standards and significantly reducing long-term energy costs.
IV. Product Parameters
|
NO |
Parameter Name |
Parameter Value |
|
1 |
Capacity Range |
50kVA - 2000kVA |
|
2 |
Voltage level |
35kV / 0.4kV (customizable for 35kV and below) |
|
3 |
Working environment temperature: |
-20℃ to +40℃ |
|
4 |
Working environment humidity |
The relative humidity should not exceed 85% at 40°C |
|
5 |
Cooling methods |
Natural cooling (AN) or forced air cooling (AF) |
|
6 |
Insulation Class: |
F Class / H Class |
|
7 |
Protection Class |
IP54 (Higher protection classes available upon request) |
|
8 |
Noise level |
≤65dB (1000kVA and below) |
V. Scope of Supply
|
No |
Name |
Model |
Quantity |
Unit |
|
1 |
Epoxy resin dry type transformer |
Please refer to the actual parameters. |
1 |
Set |
|
2 |
cabinet |
Please refer to the actual parameters. |
1 |
Set |
VI. Optional Customization Solutions
We consistently uphold a customer-centric service philosophy, committed to providing our clients with deeply customized solutions. Your specific application scenarios and unique needs will receive in-depth consultation and professional analysis from our technical team. Based on this, we will flexibly adjust product specifications and technical parameters to tailor-make a precisely matched, personalized product for you.
VII. Quality
Approved by the National Transformer Quality Supervision and Inspection Center through type testing, compliant with standards such as GB 1094. Certified with ISO 9001 and ISO 14001, along with strict full-process inspections to ensure product quality and compliance.
Qualification association: We adhere strictly to globally recognized regulations and protocols, integrating environmental excellence and quality management throughout the product lifecycle.

VIII. Real-world cooperation cases

To meet the power supply adaptation requirements of export projects, we specially customized an epoxy resin dry type transformer. Based on the customer's strict requirements for voltage conversion accuracy and adaptability to high temperature and humidity environments, the product adopts a core insulation design to precisely match the power supply difference between the local 220V/60Hz power grid and the 380V/50Hz power supply of the exported equipment in China, and has the ability to operate continuously and stably in tropical environments with an average annual humidity of 85%.
IX. Application Scenarios
Epoxy resin dry type transformers, due to their safety, environmental friendliness, and stability, can be applied in the following scenarios where safety and reliability requirements are high:
- Densely populated public and commercial buildings
- Industrial and infrastructure projects with stringent environmental and safety requirements
- Modern facilities and new energy fields requiring high energy efficiency

X. Our Service
Our after-sales service and technical team solemnly promises
Pre-Sales Service
Consultation & Guidance: 24/7 online support with expert engineers to clarify needs, recommend solutions, and advise on pricing and processes.
On-Site Inspection: Engineers visit sites for precise measurements and environmental assessment, deliver detailed reports to support tailored system design.
Year Warranty: Covers material/manufacturing defects as per contract.
Dedicated Support: One-on-one follow-up from a specialized team for seamless assistance.
Multi-Channel Help: Support via contacts, project teams, or website; fast global coordination for repairs or replacements during warranty.
XI. Product usage tutorials, solutions, and technical problem notifications
Pre-operation Inspection: Establishing a Solid Foundation for Start-up
3 Core Steps for System Setup:
- Foundation Condition Inspection
- Insulation and Grounding Inspection
- Cooling and Ventilation Inspection
[Click here to view the complete product manual & detailed instructions >]
XII. Packaging and Transportation

XIII. Factory Strength
1. Qualification Certificates


2. Innovative technologies/capabilities

(1) High-tech enterprise certificate



3. Supply Chain Advantages
- Flexible Production Switching:
The production line possesses rapid changeover capabilities, enabling seamless transitions between standardized and customized modes to eliminate production interruptions caused by order variations.
- Rapid Response for Customization:
Establish a full-chain rapid response mechanism from demand to materials to ensure non-standard orders can swiftly enter the production phase.
- Supply Chain Resilience:
Establish a multi-source supply and modular material system to flexibly respond to material fluctuations and changes, avoiding production delays caused by raw material variations.
4. Professional production equipment (CNC)









XIV. FAQ
Q1. What could be causing an abnormally high winding temperature? How should it be handled?
Causes: Usually caused by cooling system malfunction (e.g., fan failure), prolonged overload operation, severe dust accumulation on the winding surface, or internal faults (e.g., inter-turn short circuits).
Handling: First, clean the winding and inspect/replace the faulty fan; if the temperature remains high after reducing the load, the machine must be stopped and the insulation and DC resistance tested to rule out internal faults.
Q2. What factors cause a decrease in insulation resistance? How should it be resolved?
Causes: The main causes are winding dampness, surface dirt and dust accumulation, aging insulation materials, or excessive humidity in the operating environment.
Handling: The winding should be cleaned and dried (e.g., hot air drying), and measures should be taken to reduce ambient humidity (recommended ≤85%) to fundamentally prevent moisture absorption.
Q3. What faults might be indicated by abnormal sounds heard during operation?
Causes and Handling:
"Crackling" discharge sound: This may indicate insulation breakdown; the machine must be stopped immediately for inspection and replacement of damaged insulation.
A sharp "buzzing" sound: This is often caused by overload or overvoltage, requiring load reduction or checking the mains voltage.
A continuous friction sound: This may originate from loose core clamps or worn fan bearings, requiring tightening or replacement as needed.