Home - Article - Details

How does the cooling system of the transformer interact with Transformer Winding Hot Spot Monitoring?

Sophia Miller
Sophia Miller
Sophia is a technical support engineer. She provides professional technical support and after - sales services for customers, quickly and effectively solving various problems encountered by customers in using products, and ensuring the normal operation of customer equipment.

If you’ve ever stood next to a substation on a sweltering summer day, you know transformers work super hard to keep the power flowing— and if they overheat, bad things happen. As a supplier focused on transformer winding hot spot monitoring, I’ve spent countless chats with substation techs, grid operators, and plant engineers who tell me the same thing: hot spots are the #1 silent killer of transformer lifespan. But here’s the thing most folks don’t fully grasp: the cooling system doesn’t just cool things down—it’s tied directly to how well we monitor those hot spots. Let’s break that down, no boring jargon overload, just real talk about how these two systems dance together.

Transformer Winding Hot Spot Monitoring factoryTransformer Winding Hot Spot Monitoring

First, let’s get on the same page: what’s a winding hot spot, exactly? It’s that tiny, super hot spot on a transformer’s copper windings, usually from uneven heat distribution—think of a pizza where one slice is charred while the rest is warm. That charred spot? Over time, it breaks down the insulation, causes weird stuff like partial discharges (you can check that with an Online Partial Discharge Monitoring System for Transformer, by the way, super useful companion tool), and can even lead to a total transformer blowout. Now, the cooling system’s job is to spread that heat out so it doesn’t turn into a hot spot. But how do they interact? Let’s dive into the day-to-day of a transformer to see this play out.

Take an oil-immersed transformer, the most common type out there. Its cooling system might be ONAN (oil natural, air natural)—think a big radiator with fans blowing on it—or ONAF (oil natural, air forced) where the fans kick in when things get toasty. Either way, the oil picks up heat from the windings, carries it to the radiator, dumps the heat, and loops back. But here’s the catch: if the cooling system is acting up, that loop breaks, and suddenly parts of the winding get way hotter than others. That’s where our Transformer Winding Hot Spot Monitoring tool comes in—we track those uneven temps in real time. But if the cooling system’s not working right, our readings don’t mean squat. For example, if a radiator fan dies, the oil flow slows down, so the hot oil can’t carry heat away fast. Our monitoring system might show a winding temp spike, but if we don’t check the cooling system, we might miss that the real issue is a faulty fan, not the winding itself. I’ve seen this happen so many times: a substation tech calls panicking because their hot spot alarm went off, but turns out their ONAF fans were clogged with dust, so the cooling couldn’t keep up. Fix the fans, the hot spot temp drops, no winding damage—simple, but only if you link the two systems.

Another example: forced-oil, forced-air (FOFA) cooling systems, which are used for big industrial transformers. These have oil pumps that push oil through the windings at high pressure. If a pump starts to fail, oil flow becomes uneven—some parts of the winding get tons of cool oil, others get barely any. Our hot spot monitoring will pick up that uneven temp: say, Phase A winding is at 110°C, Phase B is at 135°C. But if the operator doesn’t check the cooling system’s pump performance, they might just crank down the load to fix it, which wastes power. Instead, pairing our monitoring with cooling system data (like pump flow rates, valve positions, and radiator temperatures) lets you pinpoint exactly where the gap is. We actually build this cross-system data connection into our Transformer Winding Hot Spot Monitoring tools now—they integrate with the cooling system’s SCADA feeds, so you don’t have to toggle between 5 different screens to see what’s going on. That’s a game-changer for folks who are already swamped with maintenance tasks.

Wait, let’s talk about hot spot modeling, because that’s where the interaction gets technical (but in a useful way). Most modern hot spot monitoring doesn’t just use temperature sensors—they use algorithms that calculate hot spot temp based on top-oil temp, load, and cooling performance. If the cooling system’s efficiency drops, the algorithm has to adjust its calculations. For example, if the radiator’s heat transfer is lower because the fins are dirty, the top-oil temp goes up even if the load is the same. The hot spot model has to account for that to give you an accurate reading. I remember a client who had their transformer shut down because the hot spot monitor said 145°C, which is above the safe limit. But when we cross-checked with cooling system data, we saw the radiator fins had 2mm of dust buildup, so heat transfer was only 70% of its rated value. We adjusted the hot spot model to account for the reduced cooling efficiency, and the real hot spot temp was actually 128°C—well within safe range. They blew out the fins, and everything went back to normal. If we hadn’t linked the cooling data to our monitoring, they would have replaced a perfectly good winding, which would have cost them hundreds of thousands of dollars. That’s the kind of impact this interaction has.

Now, let’s get to the wear-and-tear side. Transformers age over time, and their cooling systems age too. Seals leak, pumps wear out, fans get noisy, oil gets contaminated. Each of these issues changes how the cooling system performs, which changes the hot spot’s behavior. That’s why regular checks of both systems are non-negotiable. For example, a small oil leak in the cooling loop might lower oil flow just enough to create a hot spot under high load. Our monitoring system can pick up a temp spike during peak hours, but if you pair that with a transformer dissolved gas analyzer (that’s another great tool, by the way—Transformer Dissolved Gas Analyzer looks for gas buildup from insulation breakdown), you can confirm if the hot spot is from cooling issues vs. actual winding insulation damage. I always tell clients: don’t treat hot spot monitoring like a standalone tool. It’s part of a bigger system that includes cooling, gas analysis, even core grounding (Transformer Core Grounding Current Monitor catches core faults that can also create heat—triple whammy if you miss that).

Wait, let’s touch on real-world scenarios that most people don’t think about. What about during seasonal changes? In winter, when ambient temps drop, the cooling system might be too efficient, right? Wait no—wait, in ONAN systems, cold oil is thicker, so flow is slower. So in winter, you might think you need less cooling, but actually, oil viscosity drops, so natural flow is reduced, which can lead to hot spots even when the load is low. Our Transformer Winding Hot Spot Monitoring tools have seasonal adjustment algorithms that factor in cooling system performance based on ambient temp. We had a client in Minnesota who was getting false hot spot alarms in January—turns out their oil was too cold, flow was slow, so the monitoring system (which was using summer cooling parameters) miscalculated. Once we updated the model with winter cooling data, the alarms stopped. That’s another example of how the two systems are inextricably linked.

Let’s also talk about predictive maintenance, which is huge right now. Grid operators don’t want to do reactive fixes—they want to fix stuff before it breaks. Our monitoring systems pair real-time hot spot data with cooling system data to predict when a cooling component will fail, which in turn predicts a future hot spot. For example, if our system sees that a fan’s vibration is increasing (we can pick that up via cooling system sensors), and the hot spot temp is starting to spike during low load, we can schedule a fan replacement before summer hits, when the load will be higher. That’s way better than waiting for a fan to die and causing a transformer outage during peak AC use, when everyone’s running their AC and grid demand is at its highest. I’ve seen grids save millions by doing this kind of predictive maintenance—they don’t have emergency repairs, no blackouts, no angry customers.

Now, let’s get honest about common mistakes. A lot of operators buy a hot spot monitor and then ignore the cooling system, or vice versa. Or they set the hot spot alarm too low, thinking that’ll prevent damage, but that just leads to unnecessary downtime. Or they set the alarm too high, and miss actual issues. The sweet spot is integrating the two: using cooling system data to calibrate your hot spot monitor, using hot spot data to catch cooling issues early. It’s like a team—each member has a job, but they work together to win. Our customers who do this have way fewer unplanned outages, longer transformer life, lower maintenance costs.

As someone who’s been in this game for a while, I can tell you that the biggest myth out there is that hot spots are only caused by winding defects. Yeah, bad winding workmanship or insulation damage can cause hot spots, but 30% of the time (I’ve seen this in our client data) hot spots are caused by cooling system failures. That’s a big number—so if you’re only monitoring windings and not cooling, you’re missing a huge piece of the puzzle. And if you’re only monitoring cooling and not hot spots, you might miss the exact moment when a cooling issue starts to damage the winding.

Let’s wrap this up with what this means for you, whether you’re a substation tech, grid operator, or industrial plant manager. If you want your transformer to last as long as possible (15-30 years, if you take care of it) and avoid costly outages, you can’t separate your cooling system from your winding hot spot monitoring. They work together like peanut butter and jelly—you can eat either alone, but together they’re way better. Our Transformer Winding Hot Spot Monitoring tools are built to integrate seamlessly with your cooling system, plus we work with all the other monitoring tools you might have (like that Online Partial Discharge Monitoring System for Transformer or Transformer Dissolved Gas Analyzer) to give you a complete picture of your transformer’s health.

If you’re tired of chasing hot spot alarms that don’t make sense, or dealing with unexpected outages that could have been prevented, reach out. We can help you set up a system that ties cooling and hot spot monitoring together, so you’re always in control of your transformer’s performance.

References

  1. IEEE Std C57.91-2011, IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
  2. Transformer Cooling Systems: A Practical Guide for Power Transformers, Electric Power Research Institute (EPRI), 2020
  3. Hot Spot Temperature Monitoring for Power Transformers, International Council on Large Electric Systems (CIGRE), 2018
  4. Effects of Cooling System Efficiency on Transformer Winding Hot Spot Temperatures, Journal of Power Engineering, 2021